Showing results: 241 - 255 of 340 items found.
-
cPCI Serial 3U -
Kontron
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
cPCI 6U -
Kontron
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
40-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-002 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-005 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-192-012 -
Pickering Interfaces Ltd.
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
780562-01 -
NI
Virtex-5 LX85 FPGA, 128 MB DRAM PXI FPGA Module for FlexRIO—The PXI‑7953 provides flexible, customizable I/O for LabVIEW FPGA. It includes 132 single-ended I/O lines configurable as 66 differential pairs. You can pair the PXI‑7953 with FlexRIO adapter modules that offer high-performance analog and digital I/O. Together, the two modules create a reconfigurable instrument that you can program with LabVIEW FPGA software.
-
783156-02 -
NI
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.